• Standard & Long Creeping Distance Micaver® Insulators

    Standard & Long Creeping Distance (also known as LCD or LLF) Micaver® Insulators are made with long time used lead-free Mica-glass composition. Mechanically and electrically robust, resistant to thermal shock, they are today the reference material for demanding applications such as in railway rheostatic brakes.

  • Main properties

  • Title Height (mm) Insert diameter (mm) Insert type Insert material Electrical rigidity (mn) Creepage distance (mm) Tensile strength (daN) Torsion resistance (daN.m) End flexural strength (daN) Datasheet
    *MV LLF50 50 10 FF Nickel plated Steel 20 Kv/50 Hz/1 min 102 ≥ 1900 ≥ 4.5 ≥ 400
    *MV LLF50 SS304L 50 10 FF Stainless Steel 304L 20 Kv/50 Hz/1 min 102 ≥ 1900 ≥ 4.5 ≥ 400
    MV LLF50 (12M) 50 12 FF Nickel plated Steel 20 Kv/50 Hz/1 min 102 ≥ 1900 ≥ 4.5 ≥ 400
    MV LLF50 SS304L (12M) 50 12 FF Stainless Steel 304L 20 Kv/50 Hz/1 min 102 ≥ 1900 ≥ 4.5 ≥ 400
    MV 52A 50 10 FF Nickel plated Steel 22 Kv/50 Hz/1 min 63.5 ≥ 1900 ≥ 4.5 ≥ 400
    MV 52A SS304L 50 10 FF Stainless Steel 304L 22 Kv/50 Hz/1 min 63.5 ≥ 1900 ≥ 4.5 ≥ 400
    MV 52B 50 12 FF Nickel plated Steel 22 Kv/50 Hz/1 min 63.5 ≥ 1900 ≥ 8 ≥ 400
    MV 52B SS304L 50 12 FF Stainless Steel 304L 22 Kv/50 Hz/1 min 63.5 ≥ 1900 ≥ 8 ≥ 400
    MV 52C 50 10 MF Nickel plated Steel 22 Kv/50 Hz/1 min 63.5 ≥ 1900 ≥ 4.5 ≥ 400
    *MV 52C SS304L 50 10 MF Stainless Steel 304L 22 Kv/50 Hz/1 min 63.5 ≥ 1900 ≥ 4.5 ≥ 400
    *Special minimum order quantity & lead-time. Please conctact us for further information.
    Find your Micaver insulator
    Product family
    Height
    Insert type
    Insert material
    Insert diameter
    Creepage distance
  • Search tool details

  • Related markets

     
    Industrial
    Industrial
    Trains, metro and trams using Micaver
    Railway